• Biochemistry Analyzer

    Biochemistry Analyser / Elisa Reader / Coagulation

  • Bilirubin Analyzer

  • HBA1C Analyzer

  • Biochemistry Analyzer

  • Biochemistry Analyzer

Clinical Chemistry / Coagulation / Elisa Reader

  • Main Feature
  • Technical Specification
  • Product Description

• User friendly software
• Editing of patient ID, Name (12 characters), Factor
• Print out of laboratory name & Doctor's name.
• Coagulation test like PT with Magnetic Stirrer.
• Storage of 2000 test results in the memory with patient ID.
• PS2 Keyboard connection optional.
• Lamp Saver mode.

METHODS OF CALCULATIONS
• Absorbance
• End Point with standard / factor
• Kinetics
• Fixed time
• Differential
• Coagulation
• Multipoint upto 10 standards

ASPIRATION SYSTEM
Continuous flow system with bi-directional Pump.

CUVETTES : DUAL MODE
Flow Cell of 18 µL

REMOVABLE CUVETTES
Macro, Semi Micro, Micro

Mixing by magnetic motor / stirrer INR / ISI Value % / Seconds Auto / Manual start
Parameters PT / APTT / Fibrinogen
Filter 405 nm / 630 nm.
Wells 8 position
Filters 405 nm/450 nm / 630 nm
Methods Cut-off / Multi standard with EP / KIN / Fix Time
O.D. Range 0 - 3.5A
Principle Absorption spectrometry
Range of measurement From – 0.1 to 3.0A
Nominal spectral range Automatic via filter wheel
Filters 340, 405, 450, 505, 546, 578, 630 and 670nm interference type
Bandwidth 10 nm (± 2nm)
Reading error ± 5% at 0.10 A
± 2% at 1.00 A
± 2% at 2.00 A
Light source Halogen lamp
Zero Automatic
Settings Monochromatic and Bichromatic readings.
Detector Schottkey type Photodiode - Silicon
Peltier regulated 25°, 30° & 37°C programmed
Accuracy ± 0.2°C
Flow cell of 18 µL
Removable cuvettes Macro, Semi-micro & Micro
Type Fast Thermal Graphic
Printing speed 50 mm/sec
Dots per line 384 dots/line
Paper Thermosensitive - 57 mm wide, Easy Loading
Programming On/Off test wise
Screen Graphic LCD 240 x 128 pixels
Back Light Blue LED Back lit
Keyboard Tactile Soft - Touch
Continuous flow system with peristaltic gear pump.
Sipping volume can be programmed from 200µ l to 5.0 ml.
Table of tests up to 235
Table of units up to 9 units
Quality control storage of the last 30 results
Memory 512 KB EEPROM
2 Controls per test - Normal & Abnormal
Levy-Jennings charts
Westgard's rules
Voltage 110-220 V
Frequency 50 - 60 Hz
Maximum power 110W
Temperature 10° to 40° C
Maximum relative humidity 80%
Dimensions 45 cm x 41 cm X 17
Weight 8 kgs
 

For End Point Method :
Storage of ABS for Reagent Blank.
BIO-CHEM
 
 
 

For Kinetic Test :
On Line Graph and OD. Graph Editing
Facility after the test.
Estimation of result during test / delta.
SGPT
 
 
 

Multi Point Calibration for Endpoint, Fixtime and Kinetics with graph.
GRAPH
 
 
 

• Storage of cut off value.
• Storage of multi-standard curve.
• Robotic Friendly design.
• Self Check & Self Calibration.
Cut Off / Elisa Reader
 
 
 

• Programmable measurement positions.
• Fibre Optic Guide reading chamber.
• Front loading, Self-centering strip carrier.
Strip
 
 
 

• Manual / Auto Start.
• Single Measuring Channel
• Coagulation test like. PT with parameter ISI Value / INR / Ratio    and APTT : Seconds.
COAGULATION
 
 
 

• Intregrated Incubation Timer.
• Incubation System : 9 position for test tubes.
                                  9 position for Cuvettes at 37°C